global product overviewhistorytest results company brochure purification process freshwater catalogue desalination catalogue disaster relief catalogue military catalogue desal process disaster product overviewmilitary product reference mobile unitsmilitary desalination miltary logistics military field challenges municipal applications


Test Results and Lab Report

Global Water LS3's unique 3-phase water purification systems exceeded purity and safelty standards when tetsed by an independent laboratory. We are pround to provide the people and public agencies of the world a state-of-the-art process for treating previously unpotable water from almost any source. Please contact us toll free with any questions about our Global Systems: 866-733-8686

Test Results and Laboratory Report
THE INFORMATION CONTAINED HEREIN RELATES TO THE RESULTS OF TESTING TO REQUIREMENTS OF THE NATIONAL SANITATION FOUNDATION (NSF) STANDARD NUMBER 53 (PAR 5.2.1). THE ONLY PORTION OMITTED RELATES TO THE INTERNAL CONSTRUCTION, COMPONENTS, AND MATERIALS OF THE TWO STAGE MEDIA AS THEY ARE PROPRIETARY.

THM (as CHC13) Chemical Concentration: 0.53 Unit Outflow: .04 Maximum Allowed: <0.1
Lead (as PbC 12)
Chemical Concentration: 0.13 Unit Outflow: .008 Maximum Allowed: <0.025
Fluoride
Chemical Concentration: 8.12 Unit Outflow: .098 Maximum Allowed: <1.4
Nitrate (as N)
Chemical Concentration: 30.2 Unit Outflow: 3.17 Maximum Allowed: <10.0
Barium
Chemical Concentration: 10.0 Unit Outflow: .04 Maximum Allowed: <1.0
Arsenic
Chemical Concentration: 0.37 Unit Outflow: .001 Maximum Allowed: <0.05
Cadmium
Chemical Concentration: 0.030 Unit Outflow: .006 Maximum Allowed: <0.01
Chromium VI
Chemical Concentration: 0.150 Unit Outflow: .002 Maximum Allowed: <0.05
Chromium 111
Chemical Concentration: 0.161 Unit Outflow: .003 Maximum Allowed: <0.05
Selenium
Chemical Concentration: .103 Unit Outflow: .0015 Maximum Allowed: <0.01
Mercury
Chemical Concentration: 0.006 Unit Outflow: .0007 Maximum Allowed: <0.002
Endrin
Chemical Concentration: 0.0007 Unit Outflow: .0001 Maximum Allowed: <0.0002
Methoxychlor
Chemical Concentration: 0.31 Unit Outflow: .03 Maximum Allowed: <0.1
Toxaphene
Chemical Concentration: 0.016 Unit Outflow: .0009 Maximum Allowed: <0.005
2, 4-D Chemical Concentration: 0.31 Unit Outflow: .0067 Maximum Allowed: <0.1
Silvex (2, 4, 5-TP)
Chemical Concentration: 0.031 Unit Outflow: .0067 Maximum Allowed: <0.01


LS3 Water Systems Eliminate Bacteria and Viruses

Protozoa Nematodes
Entomoeba histolytica (Amibiasis) Ascarts lumbricoides (Roundworm)
Balantidium colt (Balantidiasis)
Cryptosporidium (Criptosporidiiosis)
Giardia lamblia (Giardiasiis)
Hepatitis A and B (Hepatitis)
Poliovirus 1,2, & 3 (Poliomelytis)
Rotaviruses (Diarrhea)


Preventing Diseases Such As:

Vibrio cholera Cholera
Escherichia colt Childrens diarrhea
Travelers diarrhea
Hemorragic uremic syndrome
Hemorragic colitis
Leptospira interogans Leptospirosis
Salmonella paratyphi Paratyphoid fever
Salmonella typhi Typhoid fever
Shigella dysenteriae Bacillary dysentery
Shigella boydi/S. sonnei Shigellosis
Campillobacter jejuni Diarrhea
Yersinia enterocolitica Enterocolitis
Aeromonas Gastroenteritis
Legonella pneumophila Legioners disease and Potomac fever



LS3 Eliminates or Reduces Toxic Chemicals such as:

Organic Molecules
Detergents
Herbicides
Insecticides
Oils
Oil derivatives
Diesel fuel
Chlorine
Sulfhydric acid
Radon (radioactive)
Lead
Mercury
Iron
Cyanate

Barium
Cadmium
Cromium
Selen
Trihalometanes
Muriatic Acid



View Scanned Lab Report from Truesdale Labratory, Inc